Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1342
PROC-SAN (Process Sanity Audits)
9
PROC-SAN (Process Sanity Audits)
The Process Sanity Audits maintenance object is responsible for monitoring the
sanity of software processes in the system. If the Process Sanity Audits MO
detects that a process has gone insane (does not respond to a sanity message
within an allotted time period), the process will be restarted. If the Process Sanity
Audits MO detects that multiple processes (or a single key process) do not
respond to sanity messages within an allotted time period, a system recovery
action will be initiated.
sanity of software processes in the system. If the Process Sanity Audits MO
detects that a process has gone insane (does not respond to a sanity message
within an allotted time period), the process will be restarted. If the Process Sanity
Audits MO detects that multiple processes (or a single key process) do not
respond to sanity messages within an allotted time period, a system recovery
action will be initiated.
The Process Sanity Audits MO has no alarms and no tests. Certain errors are
logged to the Hardware Error Log for information purposes only.
logged to the Hardware Error Log for information purposes only.
Error Log Entries and Test to Clear Values
Note:
a. These errors indicate that a system recovery action has been taken
because one or more software processes failed to respond to a sanity
audit in a timely fashion. As a result of the recovery action, the system may
have temporarily suspended service for a period of time surrounding the
error.
audit in a timely fashion. As a result of the recovery action, the system may
have temporarily suspended service for a period of time surrounding the
error.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
Full Name of MO
PROC-SAN
none
none
Process Sanity Audits
Table 9-526.
Process Sanity Audits Error Log Entries
Error
Type
Aux Data
Associated
Test
Alarm Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
Any
none
10 (a)
0
none
none
none
none
204 (a)
any
none
none
none
none