Maintenance Object Repair Procedures
9-1355
RING-GEN
9
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
and Error Codes
Always investigate tests in the order presented in the table below when
inspecting errors in the system. By clearing error codes associated with the
Analog Ring Generator Initialization Test, for example, you may also clear errors
generated from other tests in the testing sequence.
inspecting errors in the system. By clearing error codes associated with the
Analog Ring Generator Initialization Test, for example, you may also clear errors
generated from other tests in the testing sequence.
Table 9-533.
Analog Ring Generator Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU
1
Analog Ring Generator
Query (#118)
Query (#118)
MAJO
R
R
ON
test environment UU r 3
Table 9-534.
Multicarrier Cabinet
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Analog Ring Generator Initialization Test (#117)
X
X
ND
Analog Ring Generator Query Test (#118)
X
X
ND
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
OLS Query Test (Carrier E) (#127) (c)
X
X
ND
OLS Query Test (Carrier D) (#127) (c)
X
X
ND
OLS Query Test (Carrier A) (#127) (c)
X
X
ND
OLS Query Test (Carrier B) (#127) (c)
X
X
ND
OLS Query Test (Carrier C) (#127) (c)
X
X
ND
Emergency Transfer Query Test (#124) (d)
X
X
ND
Cabinet Sensors Query Test (#122) (e)
X
X
ND
External Alarm Lead Query Test (#120) (f)
X
X
ND