DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1355
RING-GEN 
9
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
Analog Ring Generator Initialization Test, for example, you may also clear errors 
generated from other tests in the testing sequence.
Table 9-533.
Analog Ring Generator Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU
1
Analog Ring Generator 
Query (#118)
MAJO
R
ON
test environment UU r 3
Table 9-534.
Multicarrier Cabinet
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Analog Ring Generator Initialization Test (#117)
X
X
ND
Analog Ring Generator Query Test (#118)
X
X
ND
Battery & Battery Charger Query Test (#5) (a)
X
X
ND
AC Power Query Test (#78) (b)
X
X
ND
OLS Query Test (Carrier E) (#127) (c)
X
X
ND
OLS Query Test (Carrier D) (#127) (c)
X
X
ND
OLS Query Test (Carrier A) (#127) (c)
X
X
ND
OLS Query Test (Carrier B) (#127) (c)
X
X
ND
OLS Query Test (Carrier C) (#127) (c)
X
X
ND
Emergency Transfer Query Test (#124) (d)
X
X
ND
Cabinet Sensors Query Test (#122) (e)
X
X
ND
External Alarm Lead Query Test (#120) (f)
X
X
ND