Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1373
SN-CONF (Switch Node Configuration) 
9
SN-CONF (Switch Node 
Configuration)
A switch node carrier contains:
Up to 16 Switch Node Interface (SNI) TN573 circuit packs in slots 2 
through 9 and slots 13 through 20
One or two Switch Node Clock (SNC) TN572 circuit packs in slots 10 and 
12
An Expansion Interface (EI) TN570 circuit pack, a DS1 Converter (DS1C) 
TN574 circuit pack, or no circuit pack in slot 1
An optional DS1 CONV circuit pack in slot 21
SN-CONF errors and alarms are generated for two types of failures:
1. Failure of a board in the switch node carrier to insert (be detected by 
software).
2. A problem found by running the Configuration Audit (test #759). Test 759 
is executed for either an SNI or SNC circuit pack during scheduled 
maintenance or as part of the test board UUCSS s command.
For SNI circuit packs, test 759 queries the SNI for SNCs in the same 
switch node carrier, SNI peers, DS1 CONVs, and EI or SNI neighbors that 
the SNI can communicate with and compares this data to the 
administered data.
For SNC circuit packs, test 759 queries the SNC for SNCs and SNIs in the 
same switch node carrier that the SNC can communicate with and 
compares this data to the administered data.
Switch node carriers are part of port network connectivity (PNC). For background 
information about PNC, refer to the Maintenance Architecture and Hardware 
Configurations c
hapters and related maintenance objects.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 
 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack
resides (01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
SN-CONF
MAJOR
test board UUCSS s
Switch Node Configuration
SN-CONF
MINOR
test board UUCSS
2
2.
If the error and alarm logs display the switch node carrier location UUC, (cabinet and
carrier only), run the 
long test sequence on the active SNC in the carrier, (slot 10 or 12). If
the error and alarm logs display a circuit pack location, UUCSS, run the 
short test
sequence on the alarmed SNI.
Switch Node Configuration