Maintenance Object Repair Procedures 
9-1389
SNC-BD (Switch Node Clock Circuit Pack) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
configuration audit for example, you may also clear errors generated from other 
tests in the testing sequence.
NOTE:
Test #983 is not an actual demand maintenance test. This test number is 
used to report results of executing of the clear firmware-counters 
command. Refer to error codes for Test #777.
Configuration Audit (#759)
This test is non-destructive.
This test is run via the test board short or test board long command for SNC 
circuit packs.
For SNC circuit packs, this test queries the SNC for SNCs and SNIs in the same 
switch node carrier that the SNC can communicate with and compares this data 
to the administered data.
Failures of this test cause entries in the error and alarm logs against Switch Node 
Configuration (SN-CONF) with the board location of the SNC.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Reset Board 
Sequence
D/ND
1
1.
D = Destructive, ND = Non-destructive
Configuration Audit (#759)
X
X
ND
Failure Audit(#777)
X
X
ND
Processor Route Audit(#760)
X
ND
SNC On-Board Test(#778)
X
X
ND
TPN Test(#779)
X
X
ND
Switch Node Clock Reset Test(#780)
X
D