Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-77
Troubleshooting the Outgoing ISDN-Testcall Command 
5
The functions of the clearlist, and status commands associated with the ISDN 
Testcall are summarized below. 
clear isdn-testcall: enables you to cancel an in-progress ISDN-PRI test call and 
allow another test call to start.
list isdn-testcall: enables you to list all the ISDN-PRI trunks in use for an 
ISDN-PRI test call in the system.
status isdn-testcall: enables you to check on the progress of an outgoing test 
call. When an outgoing ISDN-PRI test call completes in a specific port network, 
another ISDN-PRI trunk from the same port network is available for testing 
(regardless of whether the status information has been displayed).
Troubleshooting the Outgoing 
ISDN-Testcall Command
If the TestCall BCC field appears on the Trunk Group Administration Form, make 
sure the TestCall BCC field indicates the correct BCC for the service provisioned 
on the ISDN-PRI trunk. The TestCall BCC values are defined as follows:
If the ISDN-PRI trunk is of type 
cbc
 make sure the TestCall Service field on the 
Trunk Group Administration Form indicates the correct service so that a network 
facility message can be sent across the ISDN-PRI network.
If the outgoing ISDN-PRI test call keeps aborting, make sure that the far-end 
device can handle DCP Mode 0 or DCP Mode 1.
NOTE:
Before attempting to make an ISDN-PRI test call to the public network (that 
is, the network is the far-end), make sure that test call service is provisioned 
by the network. The user must subscribe to Test Type 108 service and have 
the correct far-end test call number administered on the trunk group form 
for the call to be allowed.
0
Voice
1
Digital Communications Protocol Mode 1
2
Mode 2 Asynchronous
3
Mode 3 Circuit
4
Digital Communications Protocol Mode 0 (that is 
usually the default).