Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Alarms, Errors, and Troubleshooting 
5-89
Packet Bus Fault Isolation and Repair 
5
TN771D in Standalone Mode
In TN771D standalone mode, a terminal is connected to the Maintenance/Test 
circuit pack with an Amphenol connector on the back of the cabinet. This setup 
allows direct inspection of the packet bus and identifies shorted or open leads. 
This mode does not use the usual MT Maintenance User Interface and is thus 
available even if switch is not in service. When in standalone mode, the TN771D 
does not reconfigure the packet bus.
Required Hardware
TN771D: Standard or High Reliability systems may not have a TN771D in 
each EPN. (Use list configuration to determine if this is so.) When this is 
the case, one must be taken to the site. See the following section, 
Terminal or PC with terminal-emulation software: The EIA-232 (RS-232) 
port should be configured at 1200 baud, no parity, 8 data bits, and one 
stop bit. This is 
not the same configuration as for the G3-MT. If a terminal 
configured as a G3-MT is used, change the SPEED field from 9600 to 
1200 on the terminal’s options setup menu. (This menu is accessed on 
most terminals by pressing the CTRL and F1 keys together. On the 513 
BCT, press SHIFT/F5 followed by TERMINAL SET UP). Remember to 
restore the original settings before returning the G3-MT to service.
355A EIA-232 Adapter (Comcode 105 012 637).
258B Six-Port Male Amphenol Adapter (Comcode 103 923 025). A 258A 
Adapter and an extension cable can also be used.
D8W 8-wire modular cable of an appropriate length to connect the 258A 
on the back of the cabinet to the 355A adapter. The relevant Comcode is 
determined by the length of the cable, as follows:
— 103 786 786 (7 feet)(2.1 m)
— 103 786 802 (14 feet)(4.3 m)
— 103 786 828 (25 feet)(7.6 m)
— 103 866 109 (50 feet)(15.2 m)
Slot Selection for Standalone Mode
When selecting a carrier slot to use for standalone mode in a port network that 
does not already contain a TN771D, keep the following points in mind:
A port circuit slot (indicated by a purple label) should be used. The 
service slot (slot 0) 
cannot be used for standalone mode, although a 
TN771D may normally be installed there.
-5 volt power supply must be available in the carrier. (Refer to 
‘‘CARR-POW (Carrier Power Supply)’’
 in 
Chapter 9, ‘‘Maintenance Object 
Repair Procedures’’