Maintenance Object Repair Procedures 
9-1669
TBRI-BD (TN2185 ISDN Trunk-Side BRI) 
9
Reset the circuit pack with the busyout board UUCSS and reset board 
UUCSS
 commands. When reset, the circuit pack executes a set of tests to 
detect the presence of any of the faults listed above. Detection of one of 
these errors during initialization causes the circuit pack to lock-up and 
appear insane to the system. See the repair procedure in Note (a).
d. The circuit pack detects a program logic error. While no action is required, 
this error can lead to other errors against this circuit pack.
e. The circuit pack cannot update and read back NPE/NCE memory. This 
error can be ignored, but may lead to other errors against this circuit pack.
f. The TN2185 board notifies maintenance software that it has detected a 
parity error while accessing its dynamic RAM (that stores the board’s 
translation information and downloadable application firmware). 
Maintenance software resets the circuit pack.
g. Unable to write LAN Translation RAM Error (internal memory access error). 
Translation RAM locations for the call connection attempt are not available, 
and one or more RAM locations are bad due to a translation RAM 
read-back error. Reset the circuit pack with the busyout board UUCSS 
and reset board UUCSS commands. If the Circuit Pack Restart Test 
(#594) passes, then the on-board circuitry is healthy. Retire the alarm with 
the test board UUCSS long clear command. If the Circuit Pack Restart 
Test (#594) fails, replace the circuit pack.
h. Frame overrun at Packet Bus interface. Due to an on-board fault or by 
faulty data received on one of the circuit pack’s external ports. If any of the 
ports on this circuit pack is alarmed, refer to the repair procedures for 
those maintenance objects. If this error persists, maintenance software 
removes the board from service; replace the circuit pack.
i. The circuit pack is has problems transmitting/receiving data to/from the 
Packet Bus.
1793
Parity errors are detected when transmitting data to the 
Packet Bus.