9-1680
TBRI-PT (TN2185 ISDN Trunk-Side BRI Port) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
When inspecting errors in the system, always investigate tests in the order listed 
below. By clearing error codes associated with the 
Control Channel Loop Around 
Test, for example, you may also clear errors generated from other tests in the 
testing sequence.
Clear Error Counters Test (#270)
This test is nondestructive.
This test clears the various error counters associated with each TBRI-PT. This 
test passes if maintenance software is able to successfully send the downlink 
messages; the test aborts otherwise.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
BRI Local LAN Port Loop Around Test (#618)
X
D
BRI TDM Port Loop Around Test (#619)
X
D
L1 State Query Test (#1242)
X
X
D
CRC Error Counter Test (#623)
X
ND
Receive FIFO Overflow Test (#625)
X
ND
Layer 3 Query Test (#1243)
X
ND
Slip Query Test (#1244)
X
X
ND
Clear Error Counters Test (#270)
X
X
ND
NPE Crosstalk Test (#617)
X
D
Table 9-629.
TEST #270 Clear Error Counters 
Error 
Code
Test 
Result
Description/ Recommendation
Any
ABORT
Maintenance could not send the downlink message.
PASS
The message to clear the error counters of the TBRI-PT maintenance 
object has been sent.
Continued on next page