DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1716
TDM-BUS (TDM Bus) 
9
h. These errors indicate communication problems which may be causing 
message loss. TDM Bus maintenance may switch the Control Channel bus 
and/or Tone bus to the other bus. Test the TDM Bus via the test tdm P 
command and follow the procedures according to the error codes 
reported from the test. The aux data value shows the Angel id number for 
which a downlink message was lost.
Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Control Channel Test, for example, you may also 
clear errors generated from other tests in the testing sequence.
Idle Time Slot Test on TDM Bus A or B (#294)
The Idle Time Slot Test detects noisy time slots on the bus and takes them 
out-of-service. The Tone Detector circuit pack is told to listen to idle time slots 
and if it detects any noise on a time slot, it returns a failure. At the end of the test, 
any out-of-service time slots are retested to see if they are still noisy and restored 
to service if they are idle. After all the time slots have been tested, maintenance 
counts the number of bad time slots and reports the number to the technician in 
the error code field. No more than 220 time slots will be taken out-of-service on 
one bus and no more than 300 will be taken out-of-service on both buses at one 
time.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Control Channel Test on the Control
 Channel Bus (#296)
X
X
ND
Digit Detection Test on the Non-Control Channel Bus 
(#297)
X
X
ND
Idle Time Slot Test (#294)
X
X
ND