Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1722
TDM-CLK (TDM Bus Clock) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The Tone-Clock circuit pack may have a clock at the edge of its specified 
frequency. This can cause Expansion Interface circuit packs and SNI 
circuit packs to go out-of-frame or report no-neighbor conditions. This can 
is turn cause EPNs, Expansion Archangel Links (EALs), Remote Neighbor 
Links (RNLs), and/or Local Neighbor Links LNLs) to go down. When this 
error is alarmed, Clock Health Inquiry Test (#46) will fail with an error code 
of 1.
1. Replace the Tone-Clock circuit pack identified in the error log. See 
Table 9-644.
TDM Bus Clock Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
1
1.
As a general rule, any 
on board errors against the TDM Bus Clock should be resolved before pursuing any
other errors against SPE or PNC components. 
Off board clock errors may be caused by other board errors,
and should usually be addressed once any on board errors have been resolved.
Test to Clear Value
0
2
2.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test tone-clock UUC sh r 1
1(a)
0
None
MINOR
OFF
18(b)
0
busyout tone-clock UUC
WARNING
OFF
release tone-clock UUC
130(c)
None
257(d)
None
WARNING
OFF
513(e)
Any
Clock Circuit Status 
Inquiry (#148)
MINOR
3
3.
Major or Minor alarms on this MO may have been downgraded to Warning alarms based on the values
used in the set options command.
OFF
test tone-clock UUC 
769(f)
Any
Clock Circuit Status 
Inquiry (#148)
MAJOR
ON
test tone-clock UUC sh r 10
1025(g)
Any
Clock Slip Inquiry(#149)
test tone-clock UUC sh
1281(h)
1282(h)
Any
None
MINOR
OFF
1537
Any
Clock PPM Inquiry(#150)
test tone-clock UUC sh
2049(i)
Any
Standby Reference 
Health Check Test(#651)
MAJOR
3
ON
test tone-clock UUC
2305(j)
0
None
WARNING
OFF