Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1776
TIME-DAY (Time of Day) 
9
TIME-DAY (Time of Day)
The time of day contains the current year, month, day of the week, day of the 
month, hour, minute, and second. The Time of Day maintenance object is 
responsible for monitoring the time-of-day clock and raising an alarm if the 
time-of-day clock is not set or cannot be read by the software. If the time-of-day 
clock is not set or cannot be read by the software, many features such as 
Time-of-Day Routing, CDR, ISDN Call-by-Call, Duplication, and so on will be 
either inoperative or incorrect. The time-of-day clock should be set using the set 
time
 command whenever the system is initially powered up or the TN1648 
SYSAM circuit pack is replaced.
The time-of-day clock can be read with the display time command and set via 
the set time command. The time-of-day clock resides on the TN1648 SYSAM 
circuit pack and has a backup battery to save the time of day during power 
failures. If the TN1648 SYSAM circuit pack is physically removed from the carrier, 
the contents of the time-of-day clock is lost and the time of day must be set when 
the TN1648 SYSAM circuit pack is re-inserted.
Error Log Entries and Test to Clear Values
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use the display time command to display the time of day. If the time of 
day is displayed correctly, wait 15 minutes and verify that the alarm is 
retired. If the alarm has not been retired, continue with Step 3.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command To 
Run 
Full Name of MO
TIME-DAY
MINOR
set time
Time of Day
Table 9-666.
Time of Day Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
0
Any
Any
Any
display  time
247
1
1.
This error indicates that software cannot read the time-of-day clock on the TN1648 SYSAM
circuit pack. During this condition, all time stamps on Alarm Log entries, Hardware Error Log
entries, and Software Error Log entries are potentially inaccurate. In addition, any features that
are sensitive to the time of day (such as SMDR, Time-of-Day Routing, ISDN Call-by-Call) will not
function correctly.
0
none
MINOR
OFF
set time