Maintenance Object Repair Procedures 
9-1779
TONE-BD (Tone-Clock Circuit Pack) 
9
will also have a Tone-Clock circuit pack in the E carrier. This Tone-Clock circuit 
pack generates clocks and provides system tones for all carriers of the port 
network it resides on.
High Reliability Option
Systems with the High Reliability Option (duplicated SPE, simplex PNC) have one 
Tone-Clock circuit pack in each PPN control carrier, A and B. One Tone-Clock 
circuit pack will be actively generating system clock signals for PPN 
components, while the other will be in standby mode, ready to take over in the 
event of a Tone-Clock interchange. Similarly, one Tone-Clock circuit pack will be 
actively providing system tones for the PPN, while the other will be in standby 
mode. Normally, the same Tone-Clock circuit pack will be active for both tones 
and clock signals, but these responsibilities may be divided if neither circuit pack 
is able to perform both functions. The status port-network PN# command will 
indicate which Tone-Clock circuit pack is actively performing each function.
For systems using the TN2182 Tone-Clock-Detector circuit pack, tone generation 
and clock generation behaves the same as other clock boards with one being 
active and one being standby. But the tone detector ports (ETR-PTs) of the 
TN2182 are always considered available and in-service regardless of the 
active/standby state of the tones or clock for a specific circuit pack.
EPN Tone-Clock circuit pack configuration is the same as for the Standard 
Reliability Option. Each EPN Tone-Clock circuit pack will be active for both tones 
and clock signals for its port network.
Critical Reliability Option
Systems with the Critical Reliability Option (SPE duplication and PNC duplication) 
have two Tone-Clock circuit packs associated with the PPN, as in the High 
Reliability Option case, and two more Tone-Clock circuit packs for each EPN. For 
the first EPN in a cabinet, these are in carriers A and B; for the second EPN, 
where configured, they are in carriers D and E. As in the previous case, one 
Tone-Clock in each Port Network is active, supplying system clocks and tones, 
and the other is in standby mode.
Tone-Clock Interchange Strategy
Tone-Clock circuit pack interchanges are controlled both by manual intervention 
and by maintenance software strategies.
The manual interchange strategy for Tone-Clock circuit packs differs slightly 
between the PPN and any EPNs on a system.