Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-1788
TONE-BD (Tone-Clock Circuit Pack)
9
Error Log Entries and Test to Clear Values
Table 9-668.
Tone-Clock Circuit Pack Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test tone-clock PC sh
1(a)
0
Circuit pack removed
or SAKI Sanity Test
(#53)
or SAKI Sanity Test
(#53)
MINOR
ON
18(b)
0
busyout tone-clock PC
WARNING
OFF
release tone-clock PC
23(c)
0
None
WARNING
OFF
125(d)
None
MINOR
ON
126(e)
None
MINOR
ON
257
65535
Control Channel Test
(#52)
(#52)
MINOR
ON
test tone-clock PC r 20
257(f)
Any
None
513(g)
Any
None
769(h)
4358
None
1025(i)
4363
NPE Audit Test (50)
test tone-clock PC sh
1538(j)
Any
None
MINOR
ON
2049(k)
0
Clock Health Inquiry
Test (#46)
Test (#46)
MAJOR
ON
set tone-clock PC override
2305(k)
0
Clock Health Inquiry
Test (#46)
Test (#46)
MAJOR
ON
set tone-clock PC override
2561(l)
Any
None
MAJOR
ON
3329(m)
0
None
MINOR/
WARNING
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options command.
options command.
OFF
set tone-clock PC
3840(n)
Any
None
3848(o)
0
Clock Health Inquiry
Test (#46)
Test (#46)
set tone-clock PC override
3872(p)
0
None
set tone-clock PC override
3999 (q)
Any
None