Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1788
TONE-BD (Tone-Clock Circuit Pack) 
9
Error Log Entries and Test to Clear Values
Table 9-668.
Tone-Clock Circuit Pack Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test tone-clock PC sh
1(a)
0
Circuit pack removed 
or SAKI Sanity Test 
(#53)
MINOR
ON
18(b)
0
busyout tone-clock PC
WARNING
OFF
release tone-clock PC
23(c)
0
None
WARNING
OFF
125(d)
None
MINOR
ON
126(e)
None
MINOR
ON
257
65535
Control Channel Test 
(#52)
MINOR
ON
test tone-clock PC r 20
257(f)
Any
None
513(g)
Any
None
769(h)
4358
None
1025(i)
4363
NPE Audit Test (50)
test tone-clock PC sh
1538(j)
Any
None
MINOR
ON
2049(k)
0
Clock Health Inquiry 
Test (#46)
MAJOR
ON
set tone-clock PC override
2305(k)
0
Clock Health Inquiry 
Test (#46)
MAJOR
ON
set tone-clock PC override
2561(l)
Any
None
MAJOR
ON
3329(m)
0
None
MINOR/ 
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the value used in the set
options
 command.
OFF
set tone-clock PC
3840(n)
Any
None
3848(o)
0
Clock Health Inquiry 
Test (#46)
set tone-clock PC override
3872(p)
0
None
set tone-clock PC override
3999 (q)
Any
None