Additional Maintenance Procedures 
6-5
Software updates 
6
Restoring the System after an Update
During software updates, including call-preserving updates, several feature 
settings are lost. These must be manually restored afterward.
Re-enter all Maintenance Object busyouts.
Re-enter wakeup calls and do-not-disturb stations.
Restore attendant feature settings.
Notify Administration and ACD users that the update is complete.
Re-enable TTI changes by the change system-parameters features.
On the change system-parameters maintenance form, restore Alarm 
Origination, Save Translations, CPE Alarm Level and SPE Interchange 
fields and Scheduled Daily Maintenance times to their original settings.
Manually reset any speakerphones which derive power from the switch by 
pressing the button on the voice terminal.
Backing Out of a Software Update
If fatal hardware errors or memory faults prevent the update from completing, the 
system must be recovered and the update backed out. If the update command 
has already been entered, follow normal escalation procedures. Backing out 
after this point is hazardous and may leave the system in a corrupted state.
Software Update Procedure 
 Simplex SPE
After making the preparations described above, execute the following sequence 
of steps, entering the commands shown in bold type. This part of the procedure 
normally takes about 3 1/2 hours. Screen output for each command is described 
in 
Chapter 8, ‘‘Maintenance Commands’’
. If errors are encountered after entering 
the 
update software command, follow normal escalation procedures. Avoid 
touching the keyboard while the save or upgrade commands are running since 