Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1914
VC-DSPPT 
9
Error Log Entries and Test to Clear Values
Notes:
a. This port has been busied out by the busyout port UUCSSpp command.
b. The VC DSP Port NPE Crosstalk Test(#1103) failed.
c. The VC DSP Port Local TDM Loopback Test(#1104) failed. Run the Long 
Test Sequence.
d. A critical hardware failure has been detected on the circuit pack. Reset 
the port by the busyout port UUCSSpp and reset port UUCSSpp 
commands. If the VC Reset DSP Test (#1106) passes, then the on-board 
circuitry is healthy. Retire the alarm with the test port UUCSSpp long 
clear
 command.
e. The VC DSP port reported loss of framing on the Service Channel between 
the VC and MMI circuit packs.
f. The VC DSP Port DSP Loopback Test (#1105) failed.
g. The DSP corresponding to this port on the VC circuit pack reported a 
firmware error. No action is required.
Table 9-706.
VC-DSPPT Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/ Off 
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If all test pass, run the long test sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
18 (a)
0
busyout port UUCSSpp
WNG
OFF
release port UUCSSpp
257 (b)
Any
NPE Crosstalk Test (#6)
MIN
ON
test port UUCSSpp 1 r 3
513 (c)
Any
VC DSP Port Local TDM 
Loopback Test (#1104)
MIN
ON
test port UUCSSpp sh r 3
778 to 
781 (d)
Any
VC Port Reset DSP Test 
(#1106)
MAJ
ON
See note (d)
1025 (e)
WNG
ON
1281 (f)
Any
VC DSP Port DSP 
Loopback Test #(1105)
MIN
ON
test port UUCSSpp sh r 3
3840 (g)