Maintenance Object Repair Procedures
9-1926
VC-SUMPT
9
Error Log Entries and Test to Clear Values
Notes:
a. This port has been busied out with the busyout port UUCSSpp
command.
b. The circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, replace or reinsert the circuit pack.
c. The NPE Crosstalk Test(#1103) failed.
d. The VC Summer Port Local TDM Loopback Test(#1100) failed.
System Technician-Demanded Tests: Descriptions
and Error Codes
and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the NPE Crosstalk Test, for example, you may also
clear errors generated from other tests in the testing sequence.
error codes associated with the NPE Crosstalk Test, for example, you may also
clear errors generated from other tests in the testing sequence.
Table 9-712.
VC-SUMPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If all test pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
18 (a)
0
busyout port UUCSS
WNG
OFF
release port UUCSSpp
130 (b)
WNG
ON
test port UUCSSpp sh
257 (c)
Any
Control Channel Loop Test
(#52)
(#52)
MIN
ON
test board UUCSSpp 1 r 3
513 (d)
Any
VC Summer Port Local
Loopback Test #(1100)
Loopback Test #(1100)
MIN
ON
test board UUCSSpp sh r 3
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk Test (#6) (a)
X
D
TDM Loopback Test (#1100)
X
X