Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1942
XXX-BD (Common Port Circuit Pack) 
9
Error Log Entries and Test to Clear Values
Notes:
a. Error type 1 indicates the circuit pack has stopped functioning or has 
been physically removed from the system. This error type does not apply 
to ANN-BD, DETR-BD, S-SYN-BD, M/T-BD, or CLSFY-BD. The alarm is 
logged approximately 11 minutes after removal of the circuit pack or 
failure of the SAKI Sanity Test (#53).
Table 9-720.
Common Port Circuit Pack Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test board UUCSS sh r 1
1(a)
0
Circuit pack removed 
or SAKI Sanity Test 
(#53)
MINOR
ON
18(b)
0
busy-out board UUCSS
WARNING
OFF
release board UUCSS
23(c)
0
None
WARNING
OFF
36 (d)
4368
none
125 (e)
None
MINOR
ON
217 (f)
0
None
WARNING
ON
257
65535
Control Channel Test 
(#52)
MINOR
ON
test board UUCSS sh r 20
257 (g)
Any
None
267 (f)
0
None
WARNING
ON
513 (h)
Any
None
MINOR
ON
test board UUCSS sh
769 (i)
4358
None
1025 (j)
4363
NPE Audit Test (#50)
test board UUCSS l r 20
1281 (k)
Ringing Application 
Test (#51)
MINOR
ON
test board UUCSS r 2
1538 (l)
Any
None
WARNING/ 
MINOR
ON
1793 (m)
Neon Test (#220)
MINOR
ON
test board UUCSS r 2
3840 (n)
Any
None
3999 (o)
Any
None