Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-28
Facility test calls 
6
Out-of-Service Time Slot Test Call
This call can be used to determine if there are any out-of-service time slots on the 
TDM bus of a specified port network. If there are, you will be connected to one. 
By listening to noise on the time slot and selectively removing circuit packs, you 
may be able to isolate the source of interference.
To place the call:
1. Dial the FAC described above and listen for dial tone.
2. Dial the port network number followed by **** and listen for one of the 
following tones:
3. Repeated test calls will alternate between out-of-service time slots on TDM 
bus A and TDM bus B.
System Tone Test Call
This test connects the voice terminal to a specific system tone.
To place the call:
1. Dial the FAC described above.
2. Dial the port network number followed by * and the two-digit tone 
identification number from the following table.
3. Listen for one of the following tones:
NOTE:
For a definition of Call Progress Tones see 
DEFINITY 
Communications System Generic 3 System Descriptions and 
Specifications, 555-230-206, Chapter 11.
Reorder tone
There are no out-of-service time slots on the 
specified port network.
Confirmation tone
Connection is made to an out-of-service time 
slot.
Intercept tone 
The number entered is not a valid tone number.
Reorder tone 
Inter-PN resources are not available.
System tone 
The specified tone will be heard if it is functioning.