Additional Maintenance Procedures 
6-34
Analog Tie Trunk Back-to-Back Testing 
6
Analog Tie Trunk Back-to-Back Testing
The TN760 circuit pack can be configured for back-to-back testing (also known 
as connectivity testing) by making translation and cross-connect changes. This 
testing configuration allows for the connection of Tie Trunks back-to-back in the 
same switch to verify the operation of Tie Trunk ports. The tests can be 
performed in either the E&M or simplex modes. (Refer to 
DEFINITY 
Communications System Generic 1 and Generic 3 Installation and Test, 
555-230-104, for instructions on how to make connections at the cross-connect 
field).
E&M Mode Test Procedure
1. At the administration terminal, enter list configuration trunks to 
determine which ports are assigned on the Tie Trunk circuit pack.
2. Enter display dialplan command to determine the Trunk Access Code 
(TAC) format.
3. Enter display port xxx for all ports defined in Step 1. This displays the 
trunk groups of which the ports are members. See 
Errors, and Troubleshooting’’
 for details of how to remove and replace port 
circuit packs.
4. Insert the circuit pack back into the slot.
5. Enter display trunk xxx p for each trunk group identified in Step 3. This 
command displays the specified trunk group on the administration 
terminal screen and prints a hard copy on the printer. Save this data for 
later use.
6. Remove all members defined by these ports from the trunk group(s) using 
the change trunk xxx command.
7. Remove the Tie Trunk circuit pack from the carrier slot.
8. Set the dip (option) switches for each of the two ports to be tested on the 
Tie Trunk circuit pack to “E&M mode” and “unprotected.”
9. Enter add trunk n to add a new (test) trunk group. Then enter information 
for the following fields:
Group Type 
tie
TAC 
Use trunk access code obtained from dial 
plan
Trunk Type (in/out) 
wink/wink
Port 
Assign two of the ports from the tie trunk.
Mode 
E&M for both ports
Type 
Specify one port as t1 standard and other 
port as t1 compatible.