Additional Maintenance Procedures 
6-38
Terminating Trunk Transmission Testing 
6
3. Enter add trunk n to add a new (test) trunk group. Then enter information 
for the following fields:
4. Locate the Tie Trunk port terminal connections at the cross-connect field. 
Consult the appropriate table above for either 110-type or 66-type 
hardware.
5. At the cross-connect field, disconnect outside trunk facilities from the 
Analog Tie Trunk ports and mark the disconnected wires for later when the 
Tie Trunk ports are placed back into normal operation. The D Impact Tool 
(AT-8762) is required to perform this step.
6. Use jumper wires (DT 24M-Y/BL/R/G) and the D Impact Tool to connect 
wiring between the two ports assigned in Step 4 at the cross-connect field. 
For example, if the two ports on the Analog Tie Trunk circuit pack are ports 
1 and 2, connect the wirings as shown below:
7. Repeat Steps 13 through 16 of the E & M Mode Test Procedure.
Terminating Trunk Transmission 
Testing
The Terminating Trunk Transmission (TTT) (non-interactive) feature provides for 
extension number access to three tone sequences that can be used for trunk 
transmission testing from the far end of the trunks.
Group Type 
tie
TAC 
Use trunk access code obtained from dial 
plan.
Trunk Type (in/out) 
wink/wink
Port 
Assign two of the ports from the tie trunk.
Mode simplex
Type 
type 5
Port 1
connected to
Port 2
(type 5)
(type 5)
(simplex)
(simplex)
T1
connected to
T12
R1
R12
T11
T2
R11
R2