Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Additional Maintenance Procedures 
6-42
Automatic Transmission Measurement System (ATMS) 
6
Running ATMS Tests
(Test Analog-Testcall Command)
ATMS test calls can be originated either on demand or according to the ATMS 
Test Schedule. Test schedules are set up with test-schedule commands which 
are described in 
DEFINITY Enterprise Communications Server Release 5.4 
Administration and Feature Description.
Demand test calls are originated by the test analog-testcall command. You can 
specify testing of an entire trunk group, an individual trunk, or all trunks on a 
single circuit pack. Trunks can be addressed by either group/member numbers 
or circuit pack/port locations. The type of test call, the number of the testing line 
on the far-end switch and various other parameters must be administered on the 
trunk group form before the command can execute.
Table 6-7.
ATMS Administration
Form
Field
Entry/Remarks
System-parameters 
customer options
ATMS?
y   (You must logoff/login in order for 
changes on this form to take effect.)
Station
Extension
At least one TN711 analog port must 
be assigned.
Port Number
UUCSS01 where UUCSS is the 
location of any TN771
Port Type COR
105TL
The number of a COR that has 
testing enabled (see next form)
Class of Restriction
Facility Access Trunk Test
y
Trunk Group
Maintenance Tests?
ATMS Thresholds (page 4 
of form)
y
This page is used to specify 
performance thresholds, the type 
and access number of the far-end 
TTL, and system response to test 
failures.
Hunt Group
(Optional, for incoming test calls) If 
the system has several TN771s, you 
can use this form to make up a hunt 
group of TTLs so that one extension 
can be used for the whole pool.
ATMS Trunk Test 
Schedule
(Optional) To set up a test schedule, 
see Chapter 4 of 
Generic 3 V2 
Implementation, 555-230-653.