DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
LED Interpretation 
7-9
DS1 CONV (TN574/TN1654) Circuit Pack LEDs 
7
DS1 CONV (TN574/TN1654) Circuit 
Pack LEDs
The TN574 and the TN1654 LEDs provide an indication of the state of the DS1 
Converter and facilities, and are covered in the following sections of this 
document.
TN574 Circuit Pack LEDs
Seven LEDs provide an indication of the state of the DS1 Converter (DS1 CONV) 
TN574 circuit pack and the DS1 facilities. The top group has the standard red, 
green and yellow LEDs. The red and green LEDs have the traditional meaning, 
where red indicates an alarm condition, and green indicates testing in progress. 
The four green LEDs on the bottom indicate the status of the DS1 facilities (see 
following section).
Table 7-3.
Switch Node Interface Yellow Led Flashing States
LED on
LED off
Condition
0.1 sec
0.1 sec
Fiber Out-of-Frame. This state indicates a failure of test 
#238, which may be caused by absence of the opposite 
end EI or Switch Node Interface, a broken or missing 
fiber, or a missing lightwave transceiver on either 
endpoint.
0.5 sec
0.5 sec
In Frame 
 No Neighbor. This state corresponds to a 
failure of test # 237, usually due to a failure of this SNI, 
or the EI or SNI at the opposite of the fiber. This 
condition may also be due to a faulty Switch Node 
Clock.
solid on
SNI Active. This is the normal state for an active SNI.
solid off
SNI Standby. This is the normal state for a standby SNI 
in systems with a duplication option.