DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-10
Common Abort and Fail Codes 
8
Common Abort and Fail Codes
Table 8-3
 lists common error codes associated with abort and fail results for 
busyout, release, test, and reset commands. In addition to these, many 
maintenance objects have other unique error codes.
Table 8-3.
Common Error Codes for Busyout, Release, Test, 
and Reset Commands 
Error 
Code
Command 
Result
Description/Recommendation
ABORT
System resources are unavailable to run command. 
1. Try the command again at 1-minute intervals up to 5 times.
0
ABORT
Internal system error. 
1. Retry the command at 1-minute intervals up to 5 times. 
1005
ABORT
A DS1 interface circuit pack could not be reset because it is 
currently supplying the on-line synchronization reference. 
1. Use the set sync command to designate a new DS1 
interface circuit pack as the on-line reference, then try the 
reset again.
1010
ABORT
Attempt was made to busyout an object that was already busied 
out.
1011
ABORT
Attempt was made to release an object that was not first busied 
out.
1015
ABORT
A reset of this circuit pack requires that all maintenance objects 
on it be in the out-of-service state. 
1. Use the busyout board command to place all objects on the 
circuit pack in the out-of-service state, and try the reset 
again.
1026
ABORT
The specified TDM bus cannot be busied out because the 
control channel or system tones are being carried on it. You can 
use the set tdm PC command to switch the control channel and 
system tones to the other TDM bus.
1030
ABORT
This command is not allowed on a circuit pack on the standby 
SPE.
Continued on next page