Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-70
display alarms 
8
Defaults
All alarms will be displayed.
Parameters
Help Messages
If the technician presses HELP after entering “display alarms” the following 
message will be displayed:
[’print’ or’schedule’]
Error Messages
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
 Command resources busy; Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
 All maintenance resources busy; try again later
From Input
After entering the command display alarms, the system technician will be 
presented with an options form.
print
This will cause the report to be printed if a printer is linked to the SAT.
schedule
When the “schedule” option is specified, the command is validated and then 
a scheduling form is displayed to allow the technician to schedule execution 
of the command. The command is then placed in the command queue and 
is executed at the specified time. The information displayed by the 
command is sent to the system printer instead of the screen. Refer to the 
Report Scheduler and System Printer feature specification [4] for more 
details.
There are no parameters entered on the command line, parameters are 
selected on the hardware alarm report form instead.
Alarm 
Types
The type of alarm to be displayed is specified by placing a “y” or “n” in 
the alarm type fields. The technician can choose a combination of active 
alarms, major, minor, warning, or resolved alarms.
Interval
Display alarm records for the last (m)onth, last (h)our, last (d)ay, last 
(w)eek, or (a)ll. The default is all.