Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-75
display alarms 
8
Output
After valid options are entered by the technician, an alarm report is displayed. 
The data displayed on this form will be:
Port
The location of the alarmed object. For installed circuit packs, the 
location is displayed as cabinet-carrier-[slot]-[circuit]. For Port 
Network-related objects, the location is displayed as PN UUB, where 
“UU” is the Port Network number and B is the bus (A or B). For Fiber 
Link-related objects, the location is displayed as x a-PNC where “x” is 
the Fiber Link number and “a” is the PNC side (A or B). This is the 
same identifier as used by the alarm log. 
Maintenance
Name
The logical name of the MO which has been alarmed.
On Brd
Whether the fault detected is on the associated circuit pack, or an off 
board element connected to the circuit pack.
Alt Name
The alternate means of identifying the MO. This field contains the 
extension when the object is a station, and it contains xxx/yyy when the 
object is a trunk, where xxx is the trunk group number and yyy is the 
member number. It contains P/xxx when the object is a private CO line, 
where xxx is the private CO line group number.
Alarm Type
MAJOR, MINOR, or WARNING. This is an indicator to the seriousness 
of the alarm raised.
Service 
State
RDY (ready for service), OUT (out of service), or IN (in service). This is 
the current service state of the station and trunk ports shown. If a blank 
is displayed in this field it means that no service state is associated 
with the MO. 
Ack?
The columns under the “1” and “2” headings denote if the alarm has 
been acknowledged by the first and second OSS telephone numbers, 
respectively. A “y” in this field means that the alarm has been 
acknowledged. An “n” means that the alarm has not been 
acknowledged. A “c” means that the alarm resolved and cleared and 
the alarm notification was acknowledged. A blank means that there will 
be no attempt to report the alarm.
Date 
Alarmed
Day, hour, and minute of alarm.
Date 
Resolved
Day, hour, and minute of resolution. For active alarms this field is zero 
(0).