Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-17
SPE Duplication 
1
Standby SPE Availability
The STBY-SPE maintenance object is responsible for testing of the standby SPE 
so that any faults that would prevent it from being available for service can be 
isolated and repaired. Various factors affect the availability of the standby SPE:
The condition of the individual hardware components of the standby SPE, 
including circuit packs, power supplies, cables and other supporting 
components.
Loss of power in an SPE due to power supply or power delivery 
components is discussed under the condition SPE-Down. If a circuit pack 
in the standby SPE that is critical to call service has failed, the standby will 
not be able to become active. Maintenance testing of the standby SPE 
allows isolation and repair of component problems so that the standby can 
be made available again.
Standby memory content
Each write operation in active memory is shadowed to the corresponding 
location in the standby SPE’s memory. The standby memory should be in 
agreement with the active in order to support an interchange that will 
preserve call, feature and translation information. Maintenance software 
tracking the STBY-SPE MO aims to keep the two memories in agreement.
Standby State-of-Health (SOH)
The Duplication Interface circuit packs maintain a state-of-health value 
which reflects the availability of the standby SPE. If the Standby SPE’s 
state-of-health level is too poor, it cannot automatically be interchanged 
into (made active).
Standby SPE-Down
If the standby SPE is completely dead and held reset by its SYSAM (in 
SPE-Down), or the standby SPE has no power, it is unavailable for service.
System Time-of-Day
If the Time-of-Day clock of the standby SPE is substantially out of synch 
with the active, interchanges could be more disruptive to service than 
desirable.
System software running on both active and standby SPEs attempts to ensure 
that the standby SPE is kept fully available in terms of the above factors. The 
health of both the active and standby is tracked as a State-of-Health (SOH) 
value.