Maintenance Commands 
8-178
reset packet-interface 
8
The cabinet number defaults to 1. The carrier must be specified only for PPNs 
with duplicated SPEs.
reset packet-interface
reset packet-interface C [S]
!
CAUTION:
Resetting a packet interface is disruptive under the following conditions:
On all standard reliability systems (simplex SPE)
When SPEs in a duplicated system are locked, or handshake is down, and 
the active packet interface is reset.
When the standby SPE in a duplicated system has a state of health lower 
than the active, and the active packet interface is reset.
!
CAUTION:
In the above cases, call service throughout the system is disrupted, the 
terminal is logged off and all EPNs are unavailable during the reset interval. 
A minor alarm is logged against the circuit pack to be reset. This lowers the 
state of health of the associated SPE and may cause a spontaneous SPE 
interchange in duplicated systems.
This command resets and initializes the packet interface circuit pack hardware 
and firmware. The actual sequence of operation depends on the type and status 
of the SPEs.
When an active packet interface is reset, its links are dropped and reassigned to 
the remaining in-service packet interface circuit packs. These links are not 
migrated back to the packet interface after the reset. A level 2 (Cold-2) or greater 
system restart is required to redistribute the links equally among all active packet 
interfaces, including the one that was reset.
Simplex SPE
For standard reliability systems the specified packet interface circuit pack is 
simply reset. Failure of the reset can lead to the circuit pack being placed in the 
out-of-service state. When a packet interface is out of service, scheduled, 
periodic, error and demand testing of the circuit pack is prevented and it is not 
used for links. The circuit pack returns to the in-service state upon passing the 
reset. A level 2 (Cold-2) or greater system restart is then performed to distribute 
the links equally among the available packet interface circuit packs.