Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-201
set options 
8
set options
This command allows the user to administer whether certain alarms are reported 
to INADS or whether they are downgraded to a minor alarm, warning alarm, or no 
alarm.
Synopsis
set options
Permissions
The following default logins may execute this command: inads, init.
Examples
set options
Description
This special command enables the technician (that is, remote user with INADS 
permission) to select which types of maintenance categories report alarms 
automatically and which types require the customer to call in. Judicious use of 
this command can reduce the number of ineffective alarms to the TSC. For the 
set options command to be effective, the default settings specified in this 
section should always be used. These settings are not intended to be changed 
on a per-system basis. Special circumstances (for example, special studies) may 
require temporary changes under the guidance of Tiers 3 and 4.
NOTE: Alarms can’t be upgraded.
Defaults
Initially, the alarm reporting options for On-board Trunk Alarms (Alarm Group 1), 
both Major and Minor, are set to “yes” (y); all others are set to “warning” (w). All 
trunk groups are associated with alarm severity group 1 by default.
Parameters
None.