Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-306
status station 
8
Output
The following display shows a typical result when status sp-link is entered.
status station
status station extension [print]
The status station command displays internal software state information for 
diagnosis. This command can help locate facilities to which the station is 
communicating.
Output
Link State:
The operational state of the link:
up
 A call is currently set up to the system printer.
down
 The link is administered but a call is not currently set up to the 
printer.
extension not administered
 An extension has not been 
administered for the system printer on the features-related system 
parameters form.
Number of 
Retries:
The number of times the switch has tried to establish the link since a 
request to set it up has been received. This field is displayed only when 
the link is down. The maximum value displayed is 999.
Maintenance
Busy?
Whether maintenance testing is being performed on the system printer 
link. A blank is displayed if the system printer link is not administered.
Type
The type of equipment administered for the extension.
Extension
The extension number specified on the command line.
Port
The location of the port assigned to the station.
Call Park
Whether the station has a call parked.
 
 status sp-link                                            SPE A
   
                       SYSTEM PRINTER LINK STATUS
 
         Link State: down
  Number of Retries: 0
   Maintenance Busy? no