Both the physical-layer protocol and the Digital Multiplexed Interface (DMI) mode 
used in the connection are dependent upon the type of 8-bit code used at layer 2 
between the DTE equipment and DCE equipment, as listed in 
Table 1-9
 and 
Table 1-10
.
Connectivity Rules
 implies the following connectivity rules:
Only the DS1 port and the analog trunk port are trunking facilities (all other 
ports are line ports). For communication over these facilities, the 
destination DCE equipment can be a hemisphere away from the system, 
and the signal can traverse any number of intervening switching systems 
before reaching the destination equipment.
Data originating at any type of digital device, whether DCP or BRI, can exit 
the system at any type of digital port — BRI, digital-line, PRI, DS1, and 
others; as long as the call destination is equipped with a data module 
using the same DMI mode used at the call origin. This is because once the 
data enters the system through a digital port, its representation is uniform 
(raw bits at layer 1, and DMI at level 2), regardless of where it originated.
Table 1-9.
Physical-Layer Protocol Versus Character Code
Protocol
Code
RS-232
Asynchronous 8-bit ASCII, and synchronous
RS-449
Asynchronous 8-bit ASCII, and synchronous
V.35
Synchronous
Table 1-10.
Digital Multiplexed Interface (DMI) Mode Versus 
Character Code
DMI Mode
Code
0
Synchronous (64 kbps)
1
Synchronous (56 kbps)
2
Asynchronous 8-bit ASCII (up to 19.2 kbps), and synchronous
3
Asynchronous 8-bit ASCII, and private proprietary