Maintenance Commands 
8-317
test alarms 
8
The following display shows a typical result when status tti is entered.
test alarms
This command tests the hardware associated with selected alarms
Synopsis
test alarms 
auto-page failures step [short | long][repeat number | clear]
Permissions
The following default logins may execute this command: system technician, 
inads, init, nms.
Examples
test alarms
test alarms step failures
test alarms long clear auto-page
test alarms long failures
Description
This command allows the technician to automatically test all of the hardware that 
is associated with the active alarms in the alarm log. This command provides a 
query form to help the user narrow the selection of alarmed objects. Once the 
form is filled out, the user presses 
ENTER
 and the hardware associated with the 
selected alarm log entries is tested. The results will be displayed in standard test 
output and status information will be displayed on the message line as the 
command progresses.
Several alarms may be logged against a single maintenance object, each alarm 
representing a different problem. Even if there are multiple entries in the alarm 
 
 status tti
                                TTI STATUS
           TTI Background Task State:  completed - all ports translated
                           TTI State:  voice
               # of Boards Completed:  30      
         # of Boards Left to Process:  0
                    Percent Complete:  100
     Elapsed Time since Task Started:  0 :0 :1