Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-320
test alarms 
8
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later
Query From Input
After entering the command test alarms, the system technician will be presented 
with an options form for alarm selection.
Alarm 
Types
The type of alarm to be tested is specified by placing a ’y’ or ’n’ in the 
alarm type fields. The technician can choose a combination of active 
alarms: major, minor, and/or warning.
Interval
Test alarms for records for the last hour (h), last day (d), last week (w) or 
all (a). The default is all.
From
Test alarm associated with records from the time specified by 
mm/dd/hh/mm, where mm month, dd is the day, hh is the hour and mm is 
the minute. If no “from” date is entered, then no checking is done. This will 
give the user all the alarms active since a month prior to the current time.
To
Test alarms associated with records to the time specified by 
mm/dd/hh/mm, where mm is the month, dd is the day, hh is the hour and 
mm is the minute. If no "to" date is entered, any alarm which is active after 
the from date will be selected.