Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-351
test maintenance 
8
The following display shows a typical result when test link 1 long is entered.
test maintenance
test maintenance [C] [short | long] [repeat # | clear] [schedule]
The test maintenance command performs hardware diagnostic tests on a the 
SYSAM (PPN) and EPN Maintenance circuit packs.
On the SYSAM, this command tests system maintenance, ACTIVE and STANDBY 
terminal ports, and the SYSAM refresh, dual port RAM, system reset and sanity 
timer functions. On the SYSAM, the long test sequence resets the circuit pack, 
terminating any local or remote SYSAM logins. To see if the last 2 tests pass, you 
must log in again. The Outpulse Relay Test and the Analog Loop Around Test are 
not run on the standby SYSAM in a duplicated SPE.
On EPN Maintenance circuit packs, the MT interface, EI link, reset and sanity 
functions are tested. The long test resets the EPN Maintenance circuit pack, 
causing a local EPN Maintenance login to drop.
The cabinet number defaults to 1. Carrier a or b must be specified only for PPN 
cabinets with duplicated SPEs.
Output
The following display shows a typical result when test maintenance a is entered.
 
 test link 1 long                                            SPE B
 
                            TEST RESULTS
 
 Port      Maintenance Name  Alt. Name Test No. Result   Error Code
 
 01C2001   PGATE-PT          5464      610      ABORT       1000
 01C2001   PGATE-PT          5464      611      ABORT       1000
 01C2001   PGATE-PT          5464      599      ABORT       1005
 01C2001   PGATE-PT          5464      613      PASS
 01C2001   PGATE-PT          5464      614      ABORT       1
 01C2001   PGATE-PT          5464      976      FAIL        2
 01C2001   PGATE-PT          5464      977      FAIL
 
 
 Command Successfully Completed