Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-354
test mssnet 
8
test mssnet
test mssnet C [short | long][repeat |clear][schedule]
The test mssnet command runs a series of diagnostic tests on the MSSNET 
circuit pack. Tests are run on both maintenance objects located on the MSSNET 
circuit pack: host-adapter (H-ADAPTR) and switch control (SW-CTL).
Parameters 
Output
The following display shows a typical result when test mssnet 1a is entered.
C
The cabinet is always 1 and need not be entered. The carrier, a or b, must be 
specified in a duplicated SPE system.
clear
The clear option does not provide a useful function for this command. MSSNET 
is used only as a command object to run tests of the MSSNET circuit pack. 
Failures of circuits on the MSSNET board cause alarms against H-ADAPTR and 
SW-CTL. Individual demand tests of those maintenance objects should be used 
to clear associated alarms.
 
 test mssnet 1a                                                   SPE A
 
                                  TEST RESULTS
 
   Port      Maintenance Name  Alt. Name Test No. Result       Error Code
 
   01A       H-ADAPTR                    822      PASS
   01A       H-ADAPTR                    823      PASS
   01A       H-ADAPTR                    824      PASS
   01A       H-ADAPTR                    825      PASS
   01A       SW-CTL                      92       PASS
 
 
 Command Successfully Completed