Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-360
test stored-data 
8
test stored-data
test stored-data [short | long] [repeat # | clear] [schedule]
The test stored-data command performs a set of consistency checks of the boot 
images and translation data on tape and disk. In particular, software vintage 
numbers and translation time stamps are compared.
The short test sequence includes only inter-device tests. These include a 
tape-to-tape, disk-to-disk and two tape-to-disk tests for SPE duplex systems with 
tape and disk devices on both carriers. The long test sequence includes up to 
four intra-device consistency checks, one for each device. Another check of the 
system boot source is included in the long sequence.
For SPE simplex systems, only one tape-to-disk inter-device test and two 
intra-device consistency checks along with the boot source check are run. The 
other tests simply do not appear in the short or long test sequences.
The lack of the optional disks does not affect which tests are run. For both SPE 
simplex systems and SPE duplex systems, aborts are returned for those tests 
which require a disk.
This command will abort if any other MSS operation has already begun.
If translations have been saved to disk since the last time the disk was backed 
up to tape (a normal situation during work sessions), tests executed by this 
command will fail.
 
 test spe-standby                                  PAGE 3      SPE B
 
  TEST RESULTS
 
 Port      Maintenance Name  Alt. Name Test No. Result     Error Code
 
 01A1      MEM-BD                      908      PASS
 01A       SW-CTL                      92       PASS
 01A1      PKT-INT                     887      PASS
 01A1      PKT-INT                     888      PASS
 
 
 
 Command Successfully Completed