Maintenance Object Repair Procedures 
9-8
AC-POWER 
9
AC-POWER for DC-Powered Systems
NOTE:
In a DC-powered Multi-Carrier Cabinet, the AC-POWER maintenance 
object exists, but serves no functional purpose. Because the system cannot 
determine the type of power used, the AC-POWER test should always pass 
or abort. The maintenance strategy for power components in DC cabinets 
is described in the 
‘‘CARR-POW (Carrier Power Supply)’’
 section.
DEFINITY supports two different cabinet types: Multi-Carrier Cabinets and 
Single-Carrier Cabinets. Single-Carrier Cabinets are used only for EPNs. Both 
cabinet types may be powered by either AC or DC power source. Environmental 
maintenance differs according to cabinet type and external power supply.
Error Log Entries and Test to Clear Values
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run
Full Name of MO
AC-POWER
WARNING
test environment UU
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
AC Power
Table 9-3.
AC Power Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU sh r 1
513
Any
AC Power Query 
Test (#78)
WARNING
OFF
test environment UU sh r 1