Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-8
AC-POWER
9
AC-POWER for DC-Powered Systems
NOTE:
In a DC-powered Multi-Carrier Cabinet, the AC-POWER maintenance
object exists, but serves no functional purpose. Because the system cannot
determine the type of power used, the AC-POWER test should always pass
or abort. The maintenance strategy for power components in DC cabinets
is described in the
object exists, but serves no functional purpose. Because the system cannot
determine the type of power used, the AC-POWER test should always pass
or abort. The maintenance strategy for power components in DC cabinets
is described in the
‘‘CARR-POW (Carrier Power Supply)’’
section.
DEFINITY supports two different cabinet types: Multi-Carrier Cabinets and
Single-Carrier Cabinets. Single-Carrier Cabinets are used only for EPNs. Both
cabinet types may be powered by either AC or DC power source. Environmental
maintenance differs according to cabinet type and external power supply.
Single-Carrier Cabinets. Single-Carrier Cabinets are used only for EPNs. Both
cabinet types may be powered by either AC or DC power source. Environmental
maintenance differs according to cabinet type and external power supply.
Error Log Entries and Test to Clear Values
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
AC-POWER
WARNING
test environment UU
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs).
AC Power
Table 9-3.
AC Power Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU sh r 1
513
Any
AC Power Query
Test (#78)
Test (#78)
WARNING
OFF
test environment UU sh r 1