Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-11
ADM-CONN (Administered Connection) 
9
ADM-CONN (Administered 
Connection)
An administered connection provides an end-to-end connection between two 
access endpoints or data modules on either the same or different switches. The 
connection is automatically established when it is administered and scheduled to 
be active.
An error is logged whenever an administered connection fails or cannot be 
established. Failures to establish a connection generate an error whether they 
occur on an initial try, a retry, a fast retry, a redial or an auto-restoration. A failed 
connection generates an error whether or not the connection is subsequently 
reestablished by fast retry, redial, or auto restoration.
An alarm is logged when an administered connection cannot be established 
either initially or after failure of a connection. Both the alarm level (none to major) 
and a failure threshold can be administered for each administered connection. 
An alarm is raised when either of the following occurs:
The number of consecutive failed attempts to establish a connection 
reaches the administered threshold.
Software determines that failure to establish a connection is due to a 
mistake in administration. See 
Table 9-5
.
Error Log Entries and Test to Clear Values
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
ADM-CONN
MAJOR, MINOR, 
or WARNING
status administered-connection N 
1
1.
Where N is an administered connection number indicated in the PORT field of the Alarm or Error Log.
Administered Connection
Table 9-5. Administered Connection Error Log Entries 
Error Type
Aux 
Data
Associated 
Test
Alarm 
Level
On/Off 
Board
Test to Clear 
Value
0, or 29 
Any
None
Any
OFF
None
1, or 28 (a,b)
Any
None
Any
OFF
None
2 (c)
Any
None
Any
OFF
None
6,21,31, or 127(d)
Any
None
Any
OFF
None
Continued on next page