Maintenance Object Repair Procedures 
9-24
ADX16A-BD (AUDIX Circuit Pack) 
9
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack combination operating in control-link (CL) mode. For 
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. 
Port-level maintenance is covered by ADX16A-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 5 slots on a port carrier. 
The tests described in this manual apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy that is described in 
DEFINITY 
AUDIX System Maintenance, 585-300-110.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
Full Name of MO
ADXCL-BD or 
\ADX16A-BD
MINOR, or 
WARNINGS
test board UUCSS sh
AUDIX Circuit Pack