Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-29
ADX16D-P (16-Port AUDIX Digital Port)
9
1000
ABORT
System resources required to run this test are not available. The port may
be in use.
be in use.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine
the service state of the port. If the port is in use, it is unavailable for
certain tests. Refer to “Status” commands in Chapter 8, for a full
description of all possible states. Wait until the port is idle before
testing.
the service state of the port. If the port is in use, it is unavailable for
certain tests. Refer to “Status” commands in Chapter 8, for a full
description of all possible states. Wait until the port is idle before
testing.
2. If the port status is idle,retry the command at 1-minute intervals for a
maximum of 5 times.
1001
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors.
under heavy traffic conditions, or it may have time slots out-of-service due
to TDM-BUS errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic,
retry the command at 1-minute intervals for a maximum of 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
be oversized for the number of tone detectors present, or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
1004
ABORT
The port was put in use during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine
the service state of the port. If the port is in use, it is unavailable for
certain tests. Refer to “Status” commands in
the service state of the port. If the port is in use, it is unavailable for
certain tests. Refer to “Status” commands in
Chapter 8, ‘‘Maintenance
Commands’’
for explanations of all possible states. Wait until the port is
idle before testing.
1020
ABORT
Test disabled via background testing. Use the status station command to
determine when the voice port is available for testing.
determine when the voice port is available for testing.
2000
ABORT
Response to the test request was not received within the allowable time
period
period
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1
2
2
FAIL
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections. Failure code 1 indicates that the
Crosstalk test failed on the primary channel. Failure code 2 indicates that
the Crosstalk test failed on the secondary channel.
causes noisy and unreliable connections. Failure code 1 indicates that the
Crosstalk test failed on the primary channel. Failure code 2 indicates that
the Crosstalk test failed on the secondary channel.
1. Replace the circuit pack (see caution at the beginning of this section).
Table 9-10.
TEST #9 NPE Crosstalk Test — Continued
Error
Code
Code
Test
Result
Description/Recommendation
Continued on next page