DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-41
ALARM-PT (ALARM PORT) 
9
b. Indicates that the circuit pack has been removed or has been insane for 
more than 11-minutes. To clear the error, reseat or replace the circuit 
pack.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Battery Feed Test, for example, you may also 
clear errors generated from other tests in the testing sequence.
Battery Feed Test (also called Port Diagnostic 
Test) (#35)
The battery feed chip provides power to the telephone equipment, signaling, 
rotary dial pulsing, transmission, and balance. This test checks the signaling and 
switchhook capabilities of the battery feed chip by terminating the port, applying 
battery, and trying to detect a current.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Battery Feed Test (#35)
X
X
ND
 Station Status and Translation Audits and Updates 
Test (#36)
X
X
ND