Hardware Configurations 
2-5
Carriers in Multi-Carrier Cabinets 
2
Port Carrier (J58890BB)
Table 2-2
 describes the function of each carrier slot.
Table 2-2. Port Carrier Circuit Pack Slots 
Slot Name
Circuit Pack
Code
Notes
POWER UNIT 
(right side)
Power Unit 
(+5V)
649A
Required for DC-powered systems. TRI 
PLS OUTPUT DC-Powered
POWER 
UNIT/ 
SERVICE
Power Unit, 
Neon
TN755B
This position is addressed as “00” in 
commands and displays. It does not 
provide tip and ring to the wall field. The 
following circuit packs are optional, 
depending on system features. One 
TN771D is required in all PPNs, and one 
in each EPN of Critical Reliability systems.
Call Classifier
TN744
Integrated 
Announcement
TN750
Speech 
Synthesizer
TN725B, 
TN433, 
TN457
Tone Detector
TN748, 
TN420B
Maintenance/ 
Test
TN771D
TONE- 
CLOCK 1
Tone-clock
TN768 
TN2182
Required as follows:
EPN with duplicated PNC: B carrier EPN 
cabinet with two PNs: D carrier 
E carrier of an EPN cabinet with two PNs 
and duplicated PNC; the Tone-clock slot 
is located with Port Slot #2. If the carrier 
does not contain a Tone-Clock board, any 
port board may be installed in this slot.
EXPN INTFC 
2
Expansion 
Interface
TN570
Optional, depending on system’s 
connectivity and duplication 
configuration; if not used for an EI board, 
this slot can accept any common port 
board.
3
If the system’s connectivity and 
duplication configuration require a 
second EI on a port carrier, it resides in 
this slot; otherwise, this slot accepts any 
common port board.
4 to 20
Port Boards
Any common port board.
Continued on next page