9-120
ANN-PT (Announcement Port) 
9
2. Performing a test board long when the circuit pack is in this state will 
yield the following abort codes:
Ports 1 AND 9 abort Test 206 with code 1024.
Ports 1 AND 9 abort Test 205 with code 2000.
Board level Tests 209 and 210 abort with code 1024.
3. The save/restore announcements command will time out with:
Error encountered, can’t complete request
 
The Announcement circuit pack lock-up can be cleared remotely by performing 
a soft reset to the circuit pack:
busy-out board UUCSS (this command drops all calls in progress on the 
Announcement circuit pack).
Reset circuit pack using the reset board UUCSS command.