DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-124
ASAI-BD (Multi-Application Platform Board) 
9
ASAI-BD (Multi-Application Platform 
Board)
Maintenance testing of the common circuit pack is handled by on-board firmware 
and SPE-controlled tests. Maintenance software queries the firmware for error 
and alarm information, status, and test results. Firmware automatically reports 
error conditions that result in SPE-controlled testing.
For MAPD board insertion, the switch makes an additional board query if any of 
the following circuit packs are inserted:
For any of the above initial board uplinks, the switch queries the board for 
administration data as well as reporting the switch software release and the 
system type.
For the native mode, the response to the board query downlink messages 
consists of several CCMS uplink messages that identify the true board code, 
vintage, suffix, emulation type, and number of reserved slots needed.
NOTE:
See also ASAI-PT/ASAI-EPT (BRI Line) maintenance documentation for 
related line information. See the following exceptions listed below:
Hyperactivity: currently, the common circuit pack is considered 
"hyperactive" if the Service Dispatcher receives 200 uplink 
messages from the circuit pack in a 10-second period. Since 
MAPD has 32 ports, the hyperactivity limit increases to 500 uplink 
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to Run 
1
1.
Where UU is the universal cabinet number (1 for PPN and 2-44 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., and so forth); and pp is the 
two digit port number (01, 02, 03, ...).
Full Name of MO
ASAI-BD
MIN
test board UUCSS pp
ASAI-BD
ASAI-BD
WRN
test board UUCSS pp
ASAI-BD
Circuit Pack
Vintage
TN754
49
TN556
49,
80 or greater
TN800
any