Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-132
ASAI-EPT 
9
System Technician-Demanded Tests:
Descriptions and Error Codes
When inspecting errors in the system, always investigate errors associated with 
the circuit pack and port first. Clearing these error codes first may also clear 
errors generated against the endpoint. When all circuit pack and port errors have 
been cleared, but errors still exist against the endpoint, investigate errors in the 
table below. By clearing error codes associated with the Signaling Link Status 
Test, for example, you may also clear errors generated from other tests in the 
testing sequence.
BRI Layer 3 Query Test (#629)
This test is not used by the ASAI-ADJ maintenance object. For information about 
this test, see BRI-SET in the maintenance documentation.
79
Service or 
option not 
implemented
Requested service or option (or combination of selected options) is not 
supported (implemented) in switch or the adjunct.
1. Consult switch and adjunct documentation to determine ASAI 
service and options supported by both switch and adjunct. 
Re-administration of the switch-administered capabilities (see 
Customer Optional Feature Form) or those of the adjunct may be 
necessary to correct the problem.
81
Invalid CRV
An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between the switch and the 
adjunct. See the CallVisor protocol reference manual.
87
Internal switch 
audit
There is an inconsistency in switch data records.
1. There is no action needed, since the switch has corrected the data 
inconsistency.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Signaling Link Status Test (#626)
X
X
ND
Table 9-51.
ASAI Cause Values  — Continued
Code
Explanation
Recommendation
Continued on next page