Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-136
ASAI-PT 
9
Error Log Entries and Test to Clear Values
Notes:
a. This error occurs when the Level 1 Status Inquiry fails or when the BRI 
circuit pack detects that Level 1 has been deactivated on the port. The 
Aux Data
 field contains one of the following values:
Refer to the repair procedures for Test #621.
b. The circuit pack is having problems transmitting data to the Packet Bus, 
thus affecting the conveyance of signalling information over D-channel. 
This error occurs when the Packet Bus transmit FIFO buffer overflows. This 
condition probably indicates a hardware problem as well. The ASAI-PORT 
alarm level is MAJOR with aux data 0. Use troubleshooting procedures for 
both on-board hardware problems and potential off-board Packet Bus 
problems. 
Table 9-53.
ASAI-PT Port Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm Level 
ASAI-PORT
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
(a)
Level 1 Status 
Inquiry (#621)
MAJ
2
2.
Major and Minor alarms may be downgraded to warning alarms based on the value used in the set 
options
 command.
OFF
test port UUCSSpp sh r 2
513 (b)
0
none
(b)
ON
1537 (c)
46210
CRC Error 
Counter (#623)
MAJ
2
OFF
3841 (d)
46208
None
3844 (e)
46223
None
3845 (f)
46211
None
3846 (g)
TEI
None
Continued on next page
Blank
This indicates that the Level 1 Status Inquiry failed.
32773
This is a message from the ASAI-Line circuit pack indicating 
Level 1 has been deactivated.