Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-154
ATM-BCH (ATM B-Channel Trunk) 
9
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate problems in the order presented in the table below. When you 
clear one of the error codes associated with a given test, you clear errors 
generated by other tests in the testing sequence. If you clear errors out of order, 
you can lose important information.
Signaling Link State Audit Test (#255)
This non-destructive test checks the status of the TN230x ATM-CES Interface 
circuit pack and the ATM D-channel (ATM-DCH) trunk, which are both important 
elements to the health of the ATM-BCH trunk.
Table 9-64.
System Technician-Demanded Tests: ATM-BCH
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
Destructive or
Non-destructive
Signaling Link State Check Test (#255)
X
X
ND
Service State Audit Test (#256)
X
X
ND
Call State Audit Test (#257)
X
X
ND
ISDN Test Call Test (#258)
X
ND
Continued on next page
Table 9-65.
TEST #255 Signaling Link State Audit Test 
Error 
Code
Test 
Result
Description/ Recommendation
None
ABORT
Internal system error
0
ABORT
1114
ABORT
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
1018
ABORT
Maintenance disabled
1. Enable maintenance. Enter y in the 
Maintenance Tests?
 field on 
page 2 of the change trunk-group form.
Continued on next page