Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-163
ATM-DCH (ATM D-Channel Port) 
9
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. Error Type 18: D-channel busied out; no calls possible over this 
D-channel.
b. Error Type 130: circuit pack removed or has been insane for more than 11 
minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board 
Check (#643). Resolve any ATM-TRK errors in the Error Log.
Table 9-69.
ATM D-channel Error Log entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp
2
2.
pp is for ports 9-32.
18 (a)
0
busyout port 
UUCSSpp
WARNING
OFF
release port UUCSSpp
130 (b)
None
WARNING
ON
test port UUCSSpp
1793 (c)
Signaling Link Board 
Check (#643)
test board UUCSS l
Continued on next page