Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-163
ATM-DCH (ATM D-Channel Port)
9
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. Error Type 18: D-channel busied out; no calls possible over this
D-channel.
b. Error Type 130: circuit pack removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit pack.
c. Error Type 1793: ATM Trunk circuit pack failed the Signaling Link Board
Check (#643). Resolve any ATM-TRK errors in the Error Log.
Table 9-69.
ATM D-channel Error Log entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp
2
2.
pp is for ports 9-32.
18 (a)
0
busyout port
UUCSSpp
WARNING
OFF
release port UUCSSpp
130 (b)
None
WARNING
ON
test port UUCSSpp
1793 (c)
Signaling Link Board
Check (#643)
Check (#643)
test board UUCSS l
Continued on next page