Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-167
ATM-EI (Expansion Interface Circuit Pack)
9
ATM-EI-related commands
The following commands may be helpful in resolving ATM-EI problems:
Replacing an ATM-EI circuit pack
Standard Reliability
1. Enter busyout atm-pnc at the DEFINITY SAT.
2. Replace the ATM-PNC circuit pack.
3. Enter release atm-pnc.
4. Wait 2.5 minutes for board insertion (firmware download).
5. Enter list sys-link to verify that the links are up.
6. Enter test board UUCSS and verify that all tests pass.
High Reliability
There are 2 ATM-EI circuit packs in the PPN, 1 in the EPN.
1. Enter busyout atm pnc at the DEFINITY SAT.
2. Replace the circuit pack.
3. Enter release atm pnc.
4. Wait 2.5 minutes for board insertion (firmware download).
5. Enter list sys-link to verify that the links are up.
6. Enter test board UUCSS and verify that all tests pass.
add atm pnc
list measurements atm
busyout/release atm pnc
remove atm pnc
busyout/release board
reset board
change system-parameters
customer-options (atm pnc)
customer-options (atm pnc)
status atm-pnc
change atm pnc
(pnc duplication)
(pnc duplication)
status cabinet
display atm pnc
status port-network
list atm oam-statistics
test board
list atm pnc