Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-170
ATM-EI (Expansion Interface Circuit Pack) 
9
A-side ATM PNC EI — Critical Reliability
1. Remove the ATM PNC connection (see 
 above).
2. Add an ATM PNC connection (see 
above).
B-side ATM PNC EI — Critical Reliability
1. Enter status pnc and ensure that the A-PNC is active.
If it is not active, request a pnc interchange using the reset pnc 
interchange
 command.
2. Enter busyout pnc-standby.
3. Enter list config car and verify that an ATM circuit pack is administered 
for the new location. If it is not, add the ATM circuit pack translations.
4. Enter busyout atm pnc 
n (connection number) b-pnc.
5. Enter change atm pnc 
n (connection number) and change circuit pack 
location for the B side.
6. Enter release pnc-standby.
Changing ATM address of a B-side ATM-PNC EI — Critical Reliability
1. Enter busy pnc-standby.
2. Enter change atm pnc 
n (connection number) and change the ATM 
address for the B side.
3. Enter release pnc-standby.
Error Log Entries and Test to Clear Values
Table 9-74.
ATM-EI Error Log Entries 
Error 
Type
Aux 
Data
1
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
2
0
Any
Any
Any
test board UUCSS
2 (a)
None
MIN
ON
18 (b)
0
busy out board UUCSS
WAR
OFF
release board UUCSS
23 (c)
0
None
WAR
OFF
125 (d)
None
MIN
ON
131 (e)
None
MIN
ON