DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-183
ATM-EI (Expansion Interface Circuit Pack) 
9
1. If Error Type 3586 is detected again, replace the circuit pack. 
u. Error Type 3841: the board received a message from the switch that it 
does not recognize, and the board responded with an inconsistent down 
link error message. This error does not affect service, and no action is 
required.
v. Error type 3842: the circuit pack received data from the Packet Bus faster 
than it could distribute the data to its endpoint. This circuit pack should be 
able to recover by itself, and no action is necessary.
w. Error Type 3999: circuit pack sent a large number of control channel 
messages to the switch within a short period of time.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in 
 when inspecting the 
errors in the system. By clearing error codes associated with the Control Channel 
Test, for example, you may also clear errors generated from other tests in the 
testing sequence.
Aux 
Data
Description
2
Packet path failed
3
Circuit path failed
4
TDM loop cannot be created
5
Packet loop cannot be created
Continued on next page
If
Then
Error Type 1538 is also 
present 
Circuit pack is taken out of service 
If Error Type 1538 is not 
present
Circuit pack is 
not taken out of service, but has 
generated 50% of the messages necessary to 
be considered hyperactive. 
This may be normal during heavy traffic.
If the error is logged during light traffic, it 
may indicate a problem with the circuit pack 
or the equipment attached to it.